THIS VERSION IS A DRAFT AND HAS NOT BEEN OFFICIALLY APPROVED
For water tight concrete, foundation or walls of structures the same ratio is always applied: 1:2:3 (C25). To obtain a precise mix use a standard measuring box:
Length of the box is L=25 cm, width is W =40 cm and depth is d =17.5 cm.
This volume represent a 50kg bag of cement to keep the weight not to heavy when mixing. Jerrycan can be used for mixing only in remote and narrow springs.
For lean concrete on foundations, use 1:3:6 ratio as follow:
Sand and gravel shall be approved by visually inspection. It should be free from debris, dusts and impurities. Recommended aggregate size is between 5mm and 20mm except if specified otherwise in specific methodology.
Good quality samples:
Bad quality sample:
Assure Concrete spacer or uniform size crushed stone used for rebars to have adequate concrete cover:
Assure the platform which mixing takes place shall be on clear surface